Click the WhatsApp button to chat, or leave a message, and we will contact you within 12 hours.
CR914 Common Rail Fuel Metering Unit (IMV/VCV) Flow Performance Test Bench
The CR914 is an advanced, intelligent testing platform designed specifically for detecting the current-flow characteristics of fuel metering units (IMV, VCV, MPROP) used in high-pressure common rail pumps. Utilizing industrial-grade control technology and high-precision German flow sensors, it provides accurate data for both pre-research and factory inspections. The system is capable of testing both normally open and normally closed metering valves of various structural designs.
With its integrated PLC and touch-screen interface, the CR914 automatically collects, processes, and plots current-flow curves, generating comprehensive data reports. It supports PWM pulse width modulation drive signals and ensures stable oil pressure at 5±0.1 bar, making it an indispensable tool for fuel system component manufacturers and professional diesel repair centers.







High Precision Measurement: Equipped with German high-precision flow sensors to ensure accurate readings at every test point (accuracy up to 0.1ml).
Automated Data Analysis: Automatically generates and draws current-flow curves and data reports, judging the qualification of loop differences and measuring points.
Versatile Testing Modes: Supports continuous testing, single-point testing, manual current adjustment, and reliability fatigue running functions.
Advanced Control System: Features a robust industrial computer with PLC and touch-screen control for fast pressure regulation and stable performance.
Comprehensive Protection: Integrated with multiple safety measures including infrared detection, safety light curtains, and automatic temperature control.
Universal Database: Includes standard database functions for preparation, storage, statistics, and printing of test results.
| Technical Feature | Specifications |
|---|---|
| Model | CR914 |
| Working Power | 380V / 50Hz |
| Working Pressure | 0 - 10 bar (Adjustable, Accuracy ± 0.01 bar) |
| Current Adjustment Range | 0 - 3A (Accuracy 0.001A) |
| Flow Measurement Range | 1 - 1000 ml/min (Accuracy 0.1 ml) |
| Automatic Temperature Control | 40 ± 2 °C (User Settable) |
| Drive Signal | PWM Pulse Width Modulation |
| Control Hardware | Industrial Computer, PLC, German Flow Sensor |



VIEWS:114 Times